Fire protection · South East Queensland

Evacuation diagrams and block plans

Clear evacuation diagrams for every evacuation route, and durable block plans for your fire alarm, sprinkler and hydrant systems, drawn from a site visit and updated whenever your building changes.

Building Fire Safety Regulation 2008 (Qld)

Services we provide

  • Site visit to confirm exits, routes and equipment
  • Evacuation diagrams for each evacuation route, correctly oriented
  • Exits, alarms, firefighting equipment and assembly areas marked
  • Fire alarm, sprinkler and hydrant block plans
  • Block plans made for outdoor use, A3 or larger
  • Updates after fit-outs and layout changes

Why it matters

In Queensland, evacuation signs and diagrams must be displayed on each evacuation route of most commercial buildings. A diagram that no longer matches the building, after a fit-out or a moved wall, can send people the wrong way in an emergency.

Block plans show attending firefighters the alarm zones, valves and boosters before they go inside. Because we service those systems, our plans match what's actually installed.

Pair it with

Fire protectionTraining & Risk Assessments

Pair new diagrams with onsite evacuation training so staff know the routes before they need them.

→

Examples

What you'll get

Illustrative examples only. Every diagram and plan we supply is drawn for your building after a site visit.

EVACUATION DIAGRAMLevel 1 · Example BuildingOfficeMeetingOpen officeKitchenStoreReceptionLobbyEXITEXITEXITWYOU ARE HEREASSEMBLY AREAFront car parkNLEGENDYou are hereExitEvacuation routeAlternative routeFire extinguisherFire hose reelManual call pointWWarden intercom pointAssembly areaIN AN EMERGENCY1. Raise the alarm2. Leave by the nearest exit3. Go to the assembly areaFire or life-threatening: call 000EXAMPLE ONLY
Evacuation diagramShows where you are, the nearest exit, alarms, firefighting equipment and the assembly area, oriented to match the wall it hangs on.
FIRE ALARM ZONE BLOCK PLANExample Building · 1 Example StreetEXAMPLE STREETZONE 1Offices · smokeZONE 2Warehouse · sprinklersZONE 3Amenities · heatZONE 4Dispatch · smokeMSBSVHBFBPYOU ARE HERE · FIRE PANELNLEGENDFBPFire brigade panelAlarm zone boundarySVSprinkler valve setHBHydrant boosterMSBMain switchboardStairsIN THE EVENT OF A FIRERING 000 TO ENSUREFIRE SERVICE RESPONSERev A · plan oriented to the panelEXAMPLE ONLY
Fire alarm zone block planMounted at the fire panel so firefighters can see alarm zones, valves, the hydrant booster and the main switchboard at a glance.

How it works

From first visit to filed certificate

  1. Free onsite assessment

    We walk the site, list every fire and electrical asset, and check where your records are up to.

  2. One quote, one schedule

    A single proposal covering both trades, with a service calendar built around your operations.

  3. Service, test and tag

    Technicians carry out the work to the relevant Australian Standards, with minimal disruption to your site.

  4. Reports, ready for audits

    Fire certificates and defect quotes land in your customer portal; electrical results and registers come straight to you.

FAQ

Evacuation Diagrams & Block Plans: common questions

Can't see your question? Call 07 3916 4344 and talk to the team.

Does my building need evacuation diagrams?

In Queensland, the occupier must display evacuation signs and diagrams on each evacuation route, unless the building's total floor area is under 300 m² (Building Fire Safety Regulation 2008, section 30). We'll confirm what your building needs at the free site visit.

What must an evacuation diagram show?

Where the diagram is displayed, the route to the nearest exit, every exit, intercom devices in common areas, manual fire alarms, firefighting equipment, the assembly area and the route to it. It must be easy to understand in an emergency, with a legend and a reasonable scale.

How often do evacuation diagrams need updating?

Your fire and evacuation plan, which includes the diagrams, must be reviewed at least once a year and updated within a month of a change such as a refurbishment or a change of use.

What is a block plan?

A durable plan mounted at the fire panel, sprinkler valves or hydrant booster, showing the building layout, alarm zones and key equipment so firefighters can find their way. The Queensland Fire Department asks for them to be at least A3, correctly oriented to the site and made for outdoor use. Paper in a plastic sleeve isn't accepted.

Free onsite quote

Get a free onsite quote

Fire protection, electrical, or both — tell us about your site and we'll arrange a free onsite assessment and one clear quote.

  • Call the team07 3916 4344
  • Email the teaminfo@hsfs.au
  • Office34 Millennium Place, Tingalpa QLD 4173
  • Business detailsABN 90 694 693 975
    QBCC Lic 15584545 · Hot Shot Fire Services Pty Ltd, licensed under the QBCC Act
    Electrical Contractor Lic 89637

24/7 priority call-out is available to existing Hot Shots clients in every region we cover, including Toowoomba (a call-out fee applies). For a fire or any life-threatening emergency, always call 000 first.

Request a free onsite quote

Takes about a minute. No obligation.

What do you need?

Commercial and industrial sites only. We'll reply to arrange a time to visit.

Thanks — your request is in. It has gone straight to our team at info@hsfs.au and we'll be in touch to arrange a time to visit. Urgent? Call 07 3916 4344.This is a preview, so nothing was sent. On the live website this request goes straight to info@hsfs.au.
CallFree quote